BUG

Concise problem statement:

Logical inversion using tilde ~ character does not work because ~ placed in netlist text in schematic canvas is ignored and does not appear in spice netlist.

Steps to reproduce bug:

Running this netlist in ngpsice.com (release 26) with
the tilde in:

ainv1 ~ind outd buff

inverts the input OK.

Removing the tilde so that line becomes:

ainv1 ind outd buff

and inserting one into:

aoutbridge1 [~outd] [out] dac

then that inverts the input OK too.

However, running this netlist in EasyEDA, then the tilde
is ignored in either location.

  • This appears to be a bug in EasyEDA.

This is the example shared on ngspice.com:

http://www.ngspice.com/index.php?public_circuit=CFHOrs

Results:

Logical inversion using tilde ~ character does not work because ~ placed in netlist text in schematic canvas is ignored and does not appear in spice netlist.

Expected results:

Placing ~ in front of a digital input signal should create a logical inversion of that input.

Url:

https://easyeda.com/editor#id=XxqICUAS0

Browser: Chrome in Kubuntu 12.04 LTS.

#Bug Reports#
#BugReports#
Bug Reports