BUG

Concise problem statement:

There is a problem with the RAD series of electrolytic capacitor package footprints.

Their pin numbering is reversed so that the + pin on the symbol is mapped to the - pin on the footprint.

  • Other RAD footprints show same fault:

https://easyeda.com/forum/topic/Electrolitic_capacitor_schematic_vs_PCB-Cc5nFlf9r

Solution:

The package pins on the RAD series of electrolytic capacitor package footprints need to be swapped.

Steps to reproduce bug:

  1. Place electrolytic cap and a resistor from EasyEDA Libs into a schematic;

  2. Connect resistor to cap, one wire to each end;

  3. Apply net labels, POS and NEG to wires to indicate cap polarity

  4. Assign a RAD-248 package to the cap symbol;

  1. Pass schematic into PCB;

Results:

Netlabel NEG connects to + package pin and POS connects to other package pin

Expected results:

Netlabel POS connects to + package pin and NEG connects to other package pin.