Hello.

I am having some strange issues with the nets on my project.  I have done several boards so far without these kinds of issues, but for some reason this project is having Nets issues that I cannot seem to solve.  I have looked over many posts but none seem to cover the issue I'm seeing.  The nets for the schematic diagram work fine. Even when I click the refresh icon next to the folder for them on this page in the design manager, the nets stay intact and there is no issues.  From this point, I can then create the PCB using the "Convert to PCB" command and it generates all of the components and the board successfully.  Even after that, I can click on the NETS folder and the nets appear to be created and linked in correctly.  However, at that point, at any time I click on the refresh button, it then breaks every single NET in the list on the PCB page, and I cannot reverse it or make it autoroute, either locally or remotely.

https://easyeda.com/CmanMalone/test-stand-pwm-control-board

Can you please assist me with this issue?

Thanks!

Update:

Really strange behavior.  So given the same scenario above, I have tried to run my local autorouter program, which has run flawlessly on my other boards, but it would stick at 0%.  I thought this was due to the issues with the NETs all being broken.  Trying all options, I just decided to run the Cloud version autorouter with all the NETs still broken, and the cloud autorouter ran and completed the routing with 0 errors, after which I can now click on the NETs refresh button and my nets on the PCB page are no longer broken.  Something seems really buggy here and I cannot determine what/where the cause is.

#General Discuss#
#GeneralDiscuss#
Others

No comments yet. Be the first to comment!