Well, this is my first post on the forum, and unfortunately, it's to report a serious error with the software. I'm using EasyEDA (Standard) in version 6.5.37. While designing a PCB, I created a ground layer using the Copper Area tool provided by the software. However, when modifying its properties and increasing the clearance to 0.75mm, a pad from a resistor became isolated (see attached screenshot). As a result, one terminal of the resistor was not connected to GND, and when checking the Design Rule Check (DRC), no warning or error was displayed. In fact, if I increase the clearance to 1mm, there are several other terminals that remain isolated. I hope this issue can be resolved as soon as possible.