Right-hand panel wont open (Chrome)
Havent used EasyEDA online standard version for a 2-3 months. Now in v6.5.22 I find that the right hand panel wont open either when I click on the arrow or when I click on the option under View menu. The arrow changes direction left/right but the panel does not open. Seems to be an issue with Chrome I am using Version 108.0.5359.99 (Official Build) (64-bit). Under Firefox 106.0.5 (64-bit) it works fine. #Schematic#
Error in 3D model for SOD-323F_L1.6-W1.3-H1.1-LS2.7
The component (diode) is reversed in the 3D model for footprint SOD-323F_L1.6-W1.3-H1.1-LS2.7 example C130415. #BugReports#
Add NET name to wire attributes in schematic
As per the title please add net name to wire attributes (in the right-click attributes list) , also display the net name when hovering over a wire. Very useful for debugging schematics and just generally making design easier esp. when working across multiple sheets. As a bonus you could also highlight/bold all wires on the same net when hovering over a wire. #FeatureRequests#
Part information doesnt line up
On the schematic below the ref designation, part name and package information for U16 and U4 dont line up. No matter what grid and/or snap size I choose, I cant get these three pieces of information to ailgn vertically. It looks untidy and unprofessional on the schematic. #Schematic#
LCSC parts: unnecessary package information, annoyance on schematics
Package information used on LCSC parts has extraneous information. For example in the schematic below U16 and U4 footprints are SOT23-6 and SOIC8 respectively yet the package name provided with the parts from LCSC has additional dimension information in the package name. It is totally unnecessary to provide dimensions because a SOT or SOIC package is a standard - no dimension information is necessary. Besides which dimensions should not be included in package names anyhow. (Is there a package naming standard?) These LCSC package names are long, unwieldy and an annoyance on schematics and in the BOM! The resistor R44 has an extra 'R' in the name - it is unnecessary. The ref des already tells you its a resistor. If I want to change the package name on these parts I end up creating a new part and the LCSC part number becomes meaningless. So I cannot process the BOM through LCSC, may as well use Digikey. #Schematic#
Footprint info on schematic error
I've started putting footprint information on schematics - its an option in EasyEDA schematic capture thats disabled by default. I'm doing this because of errors i've made where a part's footprint was not what i wanted and it sneaked through to manufactured boards, and almost impossible to fix then. I now add a check item during schematic capture QA to look at all footprints on the schematic to ensure the correct part was selected. But EasyEDA has a problem that has persisted through many versions and is still present in version V6.2.46 EasyEDA does not keep the footprint information text box in a position that I move it to, it always returns the text box to the default position that EasyEDA uses when you first place the schematic symbol. This text gets put on top of other components or text that I have placed in that default position. HOWEVER - only multi-part components are affected - single components eg a transistor or resistor are NOT affected. The trigger for this is if I make any change to the pcb layout - place a wire, move a component, save - any action it seems. An example project that demonstrates this behaviour is here https://easyeda.com/editor#id=|c344d65e2f724c4792b4cf2a26ad7f90|d9478f22b2c8465b9e2e20e2151299d5 #BugReports#
Production step produces incorrect Gerber
Preview of gerber on JLCPCB as well as 3rd party viewers shows top and bottom layers without tracks, just copper fill and drill holes. Yet photo view is correct. This is for a 2-layer board. If I remove the copper fills top and bottom, tracks are there. #PCB#
V4.11.5 "improvement"
I see that one of the improvements listed for V4.11.5 is "Remove shortcut key G" Why is this listed as an improvement, what were the issues? #GeneralDiscuss#
Rebuild copper layer problem - V4.11.9
BUG Concise problem statement: Selecting a copper area and clicking Rebuild Copper Area causes tracks from other layer(s) to show on top of currently active layer. (I have a 2-layer design not sure if this also happens with internal layers). Steps to reproduce bug: Create a copper area eg. GND net ground plane on bottom layer. This will give you a ground plane with clearances around other net objects, pads and tracks. Select the copper area border by clicking on its border (dashed line), Click Rebuild Copper Area in right-side Properties panel. Results: Tracks from the top layer appear overlaid on top of the ground plane. This is a visual issue, not a connectivity issue since the tracks are not connected to the ground plane. To remove these tracks from view, click on another layer eg. silkscreen or ratlines, then click back on the bottom layer. The top-layer tracks are no longer visible until you click on Rebuild Copper Area again. Expected results: As on previous version only SMT pads on other layers should be visible, not tracks. Browser: Chrome Before Rebuild Copper Area After Rebuild Copper Area #BugReports#
Make 'Mounted' a pcb attribute.
Feature Request Brief title for your desired feature: Make 'Mounted' a pcb attribute so that Mounted=NO means components are not placed, and the attribute has a field in the BoM. How would you like the feature to work? A component with attribute 'Mounted=NO' will not be transferred from schematic to pcb. Why is this feature important to you? As is now, if you want one complete schematic of components in your design, including those not on the pcb eg. front panel items, mains power IEC connectors and such, you cant make a pcb of that design without having to delete the components in the pcb editor. Obviously this is problematic. By excluding some components between the schematic and pcb through the Mounted attribute this will be possible. There may be Nets that throw errors if a component is not present, but this has to be handled in the application. Currently these components have to be placed in a separate project, not even a 2nd schematic in the same project! #FeatureRequests#
Error -cant convert schematic to PCB (duplicate schematics)
BUG Concise problem statement: My project has a single schematic, yet trying to convert it to PCB causes the error below (duplicate ref des, 3 schematics with same names). There are no duplicate schematics. Fixes I have tried: cloned the original, deleted the original and tried with the clone - same error. re-annotate schematic to no avail. restarted the browser. TBD: Delete project, create new one, put schematic in there. Link to project here: https://easyeda.com/FrankCA/Reflow_controller_v1_0-d495c82c6e9e4d6791221cd4a43f21c6 Browser: Chrome #BugReports#
Selectively remove solder mask for certain tracks
Feature Request Brief title for your desired feature: Selectively remove solder mask for certain tracks (eg power tracks) How would you like the feature to work? Some tracks such as high-current power tracks need to be thickened during production by adding solder to the track. This requires that the solder mask be excluded from these tracks. Can you add this as an option to the track properties? Why is this feature important to you? Currently this can be manually done by creating a manual exclusion area using solid region tool, but it it very time consuming to manually follow a track route, and if the track route changes it has to be done over again. #FeatureRequests#
Vias to other layer eg. GND not recognised
BUG Concise problem statement: Vias connecting top pads of SMT components to bottom GND plane are not recognized. Ratlines dont go away. See screen grab below. Steps to reproduce bug: Place SMT component eg. cap 1206 on top layer with one pad assigned to GND net. Create GND plane pour on bottom layer. Manually place via on cap GND pad and assign via to GND net, or create a trace from pad and switch layers along the way thereby creating a via to GND plane. Results: Ratlines showing missing GND connections still appear indicating SMT pad has not been connected to GND layer, even tho via has been placed on the pad and explicitly assigned to GND net in Via Properties box, or a manually routed track with via has been created. NOTE: I have not tested this for layers other than GND on a 2-layer design, so I'm assuming the same problem may appear for multi-layer designs. And yes, I have refreshed the copper pours by clicking on Rebuild button for each one. Photo view of bottom layer shows via pad is connected to GND plane meaning Gerber file is correct. Netlist shows error (red cross) for GND net and ratlines still remain. Expected results: Connections created by manual vias to other planes must be recognized as valid. Browser: Chrome #BugReports#
Change all component annotation text size simultaneously on silk layers
Feature Request Brief title for your desired feature: Component annotation text properties (PCB silk layers) How would you like the feature to work? On top and bottom silk layers it would be handy to be able to change the annotation text properties (height and line width) for all components simultaneously. Why is this feature important to you? On densely populated pcb the default text size is too large to be able to fit in all annotations (R21 C15 etc). Some have to go under components which is useless for debugging. To change all annotations manually is time consuming and will be reset if a component is updated or changed. This could be added to existing silk layers properties dialog where besides selecting color you could change text attributes for these layers as well. If there are production silkscreen limits for text size these could be enforced in this dialog as well. #FeatureRequests#
GUI improvement - Design Manager box
Feature Request Brief title for your desired feature: Allocate more space to component/net lists in design manager box. How would you like the feature to work? In Design Manager view in both schematic and pcb editors there is a space below the Components/Nets/DRC errors (PCB only) lists reserved for Parts pins or Net pins lists. This area is large in relation to the amount of information it normally contains. Usually there are many more components or nets in a design than pins on a single component or in a single net. There is not enough space allocated for components/nets lists even in smallish designs making it necessary for the component or net list to be scrolled, with a lot of empty space below the list that could be used to show more components or nets in the list. The pins list area should be resizable by being able to move the horizontal separator up or down with the mouse, or if thats not possible it should be reduced to a fraction of its current size and the space allocated to the components/nets lists! I would rather have to scroll the pins list (which I seldom use) to having to always scroll the components or nets lists (which I often use - its a useful feature). Why is this feature important to you? Essemtial GUI improvement for making EasyEDA more user friendly and reduce scrolling/clicking annoyance! #FeatureRequests#
Keep the last viewed field open in Design Manager
Feature Request Brief title for your desired feature: When I view one of the fields (Component or Nets) in design manager I want that same field to be open next time I return to that view. Currently in either schematic or pcb editor, if a am viewing netlist for example and I click away to another tab eg. from schematic editor to pcb editor or vice versa, the default is to open the Component list and I have to click and scroll to go back to the net I was viewing before. Really annoying when you are moving between schematic and pcb editors during board design and wanting to view specific nets in each, particularly when the net list is long and requires scrolling. How would you like the feature to work? Keep the last list you were viewing when you return to that editor tab (pcb or schematic). Does not have to be persistent between new editor sessions (when closing and re-opening a pcb or schematic) but must be persistent during the current session when you are clicking between pcb and schematic tabs. Why is this feature important to you? Removes an annoyance in EasyEDA! #FeatureRequests#
Show Net Name for wires in schematics
Feature Request Brief title for your desired feature: Show Net Name for wires in schematics How would you like the feature to work? Currently when you hover the mouse over a wire in schematic editor the wire changes color from green to red (default colors). It would be useful if a tooltip opened showing the netname for that wire, same as when you hover over a track in pcb editor. Also when you click on the wire the netname should appear as a field in the Wire properties panel same as for Track properties in pcb editor. Why is this feature important to you? It makes identifying nets and debugging much easier when comparing and moving between pcb and schematic editors. #FeatureRequests#
Redundant vias created when changing track layers
BUG Concise problem statement: Changing an existing track from one layer to another using the 'Layer' field in the 'Track Properties' box causes redundant vias to be placed where the track switches layers. These cause errors during DRC checks. Steps to reproduce bug: create new pcb, place some THP pads. Route a track between 2 pads, changing layers along the way select a track segment and change its layer in the 'Layer' field of the 'Track Properties' box Results: additional vias have been created at existing vias or pads. These cause errors during DRC checks Expected results: no additional vias should be created, and existing vias should be automatically removed if the moved track segment is adjacent to another track segment on the same layer. Browser: Chrome #BugReports#
Measure tool no longer works as expected
BUG Concise problem statement: When measuring between 2 entities (M-measure tool) the tool hangs without producing a measurement display after clicking on 2nd entity. Steps to reproduce bug: create new pcb, place 4 pads and/or vias, join any which way with tracks top and/or bottom layers using measure tool ('M') measure between any 2 entities by clicking directly ON the 2 entities Results: no measurement result is displayed - if you click on the grid but not on the 2nd entity, a measurement result is displayed Expected results: should work as advertised Browser: Chrome 61.0.3163.100 (Official Build) (64-bit) #BugReports#
Login failure
For 2 days now I CANNOT LOGIN. Errors: "CAS failure" or "Too many redirects" On multiple browsers: Chrome, IE, Firefox all latest versions I have cleared cache, cookies, history NOTHING IS WORKING and you are not getting back to me even tho I have sent MULTIPLE CHATS from your chat toast popup. What is going on? Have you been DOS'd again? PS: how did my username appear on this post if I wasnt logged in? Edit: Login working again, thank you! #BugReports#