Howto find replace a component.
Hi, are there any description on howto replace multible resistors like from 47K to 100K with only using the two lcsc part numbers in EasyEda Pro? Best regards Peter #Schematic#
Reuse block change GND orientation when used in project (Version 2.1.64)
What am I doing wrong? On the Reuse block the GND's are shown correct but when inserted the block in a project and open the block the GND's are upside down. Help #Schematic#
Easyeda Pro 2.1.57 [Warn] : Component attributes does not match the Supplier Part, It is recommended to use Device Standardization
I got 36 of the below lines, I do not know how to remove them, all components have allocated a LCSC part number. Can it be a bug? BR Erik #Schematic#
No connect flag, will not remove.
Hi, I am using Easyeda pro version 2.1.57. The problem below have been there for some timewith other versions) I have 2 "No connect flag"s I would like to remove. I remove them and save but when I reopen the page the "No connect flag"s are still there. What can I do to remove them? BR Peter #Schematic#
Hierarchy Diagram/Reuse block
Hi, I am doing something wrong. There should only be one PCB "Board1", but all my Reuse blocks have a PCB. How to fix this? Best regards Peter #Schematic#
Solved Clearance, Track to GND Copper Region
Hi, As you find below I have some rules for tracks. For track VIN the rule is 0,7 mm to everything else unless another tracks rule have higher demand. So I need 0,7 mm from VIN to GND, but this rule is not working since GND is a copper region. Then I tried to put the rule on the GND copper region, but then this rule will apply to all other tracks. So @support please help with a solution for this. Thank you. BR Peter #Skill#
Solved Strange ratline - error 40
Hi, there is a ratline going to the bottom of the picture ending in nothing (Copper pour GND). I have tried deleting components, reload net list and it will not disappear. Must say that my "GND" was at a point change to a net and this problem stayed when I renamed all to GND. @support please help BR Peter #PCB#
Solved Check DRC
Hi, suddenly today I got a lot of DRC. They make no sense, as you can see like "empty "Pin number". How do to I revert to a point where the error came? Best regards Peter #Schematic#
Solved Missing net in Design rules(Net Rule)
Hi, for some reason the Net Earth is missing as you can see in the below screen shots. Any suggestion on how to solve this are welcome. Thanks Peter #BugReports#
Howto do Power in a project with 2 or more instances of reuse block where power is seperated
Hi, Hierarchical schematic, 2 instances of the same reuse block. The 2 blocks are powered with different powers. The below solution will connect both instances power to VCC_NW, so it is not correct. It is working with the below solution but it is not nice how the VCC_NW power port is made. Any suggestions on how it is possible to use a VCC Net flag like above? BR Peter #Skill#
Clearance Error in the same footprint, how to solve this error?
Hi, I get the error "Clearance Error in the same footprint". I have a footprint with a slot region. What can I do to get rid of the error? Best regards Peter #PCB#
Net class
1. When a reuse block is selected in the schematic it could be nice if all components in the block is selected in the PCB layout 2. It could be nice in the PCB net class menu that you where able to make a net class containing other net classes. 3. In the Net Class manager it could be nice if you highlight a net class that you can see the ratlines/wires included in the class BR Peter #FeatureRequests#
Net Tie/Net Short
Net Tie/Net Short to ensure that layout is made correct and to ensure constraints are kept. Anyone having experience with this for Pro version? I am looking for 2 types 0,5 and 0,7 mm. Best regards Peter #Schematic#
Reuse block level 2
Hi, just a strange thing. Adding a Reuse Block Connections correct at the Reuse block schematic. But when adding to a Top level some capacitors "loose the connection". Only one type capacitor part no C1525 have the problem. BR Peter #BugReports#
Reuse Block with 2 instances
Hi, I have 2 Reuse Blocks powered with different Vcc's. But in the Reuse Block the power have the same name (of course) The problem is that in the net_list they are seen as the same net. How do I avoid this? Best regards Peter #BugReports#
DRC Error/Short flag
Hi, How can I solve the below error? Inserting a short, could solve this but why do the "Short flag" not work? BR Peter #PCB#
Incostistent between Block symbol and schematic
Hi, after moving around on the signals on a Block symbol, there is a mismatch between the Block symbol and the Schematic. The block symbol looks right but a ghost text "IN8B" is showing on the schematic representative. How do I repair the schematic without having to relocate everything? BR Peter #Schematic#
Import changes from schematic
Hi, I have converted a project from std to pro and redrawn the schematic with reusable blocks. All components have the exact same designator. When I import the changes from schematic to the PCB, I get the below containing all the parts the same way. How can I avoid it move all components from their original place? Best regards Peter #PCB#
Import of design changes in PCB fails
If the green line is not there between CBB3 and D8 and you exchange D8 with another diode (part) then the net names are changed when you import the updated schematic to a existing PCB. The solution is to add the "green" line. I still love Easyeda pro:-) Best regards Peter #BugReports#
Error in Step file export
Problem solved Hi, I tried using the step file generation, but inventor gave me this error. What is wrong? I have not the ability to add the step file, so I need to mail it if needed. Best regards Peter #BugReports#
Via problem
Solved. Hi again, I do not understand how the Via works. I start a wire from the ground pad of a capacitor and go outside the pad to place a ground via. But as you can see in the below screen grab, it places the via in the capacitor pad. What am I doing wrong? BR Peter #PCB#
Copper zones
Hi, 2 layer board, made a prohibit zone. The left area I would like one gnd plane, the right plane another gnd plane. No copper in the prohibit zone, so no connections between the 2 gnd's. Will this be possible? BR Peter #PCB#
TC2030-NL-FP
Hi, where do I find the TC2030-NL-FP footprint in easyeda pro? Best regards Peter #Schematic#
Local project to cloud
Hi, I started up in running mode: Half offline mode After working a while I change to Full online mode, but how do I get the local project to cloud? FYI, the project is both local and in cloud, but the cloud project is not updated for some reason. Best regards Peter #Skill#
PCB connections not matching schematic
Hi, Thanks for Pro it is great to have the Reuse Block function. Something is wrong with the sync between the schematic and PCB, if I import changes from schematic it says upto date. Are there anyway you can reset so it imports the tracks again? BR Peter #PCB#
Reuse Blocks
Hi, I am doing my first project where I use the reuse block way. All pages are reused blocks so I am wondering how to make the Top schematic. Could you explain how? No. 1 should be the Top view where all reused blocks are connected. Best regards #Schematic#
Reuse block turn the direction of the optocoublers
2 pcs optocoublers are turned in one direction, 1 pcs optocoubler in the other direction. When the block is inserted on a schematic the direction is changed to one direction for all 3 optocoublers. I am looking forward to continue with the pro software:-) I have some projects to convert to pro and use the feature of reuse block, are there any best way to do this? For me it seems that the net labels can give some challenges. #Schematic#
Footprint Naming Rule
Hi, could anybody help with the right footprint naming of this terminal (Wago 256-50x): In my case x=8 (numbers of terminals) CONN-TH_xP-P7.62_256-50x or CONN-TH_xP-P7.50_256-50x or CONN-TH_xP-P5.0_256-50x or something completely different. One importent thing every terminal have 2 pins, connected together. How should the symbol on the schematic look? Suggestions are welcome. Thank you for your effort. BR Peter #Skill#
Design rule to Design rule Clearance
Hi, Could it be possible to add a an extra parameter in the rule settings? Clearance to other rules. It should not be a difficult task. BR Peter #FeatureRequests#
Measure tool mil mm
It could be nice if the measure tool could show both mill and mm at the same time. So it works free from the Canvas Attributes, Units setup. #FeatureRequests#