Using Coplanar waveguide with ground traces for impedance controlled traces
I'd like to use a coplanar waveguide with ground approach to 50 ohm RF traces instead of stripline. Which set of formulas best suit JLCPCB for their 4 layer 7628 stackup? Would the formulae set provided in: Transmission Line Design Handbook by Brian C Wadell, Artech House 1991 page 79 apply correctly or is there a more appropiate approach? See: Brian Wadell Formula set for coplanar waveguide with ground for example. #PCB#
Thermal relief under IC's; different size vias
I have a 4 layer board and I wish to create a design rule that allows 2 different size of vias on the same GND net without causing an error. How can this be done? Specifically, in my case, normal network GND vias are .6/.3 (dia/hole mm) and I want some smaller GND vias to sit under IC's for thermal relief. When I create them the design rule checker throws an error because it wants them to be .6/.3. The smaller vias would still be within JLCPCB manufacturing guidelines. I think the issue come down to understanding how 2 sizes of vias can co-exist on the same network? #PCB#