asdasdasd
Copper Fill Islands Causing DRC Errors
I imported a project from Std to Pro. When I do a DRC check in Pro, I get many errors on the GND Copper Fill. These are isolated islands of copper fill. Sometimes a via to the GND copper fill below will fix the problem, but is there a way to avoid these errors? Image below. Std doesn't seem to care about these isolated islands. Regards, David #PCB#
davidg 2022-10-17 20:16:16 comment 1 0 Circuit Design
Pro Edition - Unable to search library for LCSC part numbers Cxxxxx - sits loading
I just started to play with the pro version and discovered in the lcsc tab of the library you can't search lcsc using their part number. I would often search lcsc website for a part, then use the lcsc part number Cxxxxxxx to search for the part in EasyEda. For example if I seach for C482013 in EasyEda Pro, the search just sits there loading. I tried the real part number and it is the same. This works in the standard edition. Update! It seems it works if you use the EasyEda tab, not the LCSC tab. #BugReports#
davidg 2022-09-25 19:24:59 comment 0 0 Bug Reports