asdasdasd
Panelize : Bad placement of positioning holes and fiducial mark they are on on v-cut
Hello, In some case, when you penalize your board,positioning holes and fiducial mark are placed on a v-cut route. JLCPCB don't like that :) Have nice day, Thank to the team for this really good tools #BugReports#
rom1nux 2021-02-23 15:57:00 comment 0 0 Bug Reports
I love the new project manager
Hello, The modification of the project manager tree is really good, When you have a lot of project and work on two or three project at time it's really really good. Thanks to EasyEDA team for continuous improvement of this wonderful tools ! Have nice day #GeneralDiscuss#
rom1nux 2020-08-03 16:43:25 comment 2 0 Others
Single circular outline PCB in removable square without panelize tools
Hello, I want to create circular PCB. I want to put this PCB into my pick and place machine with linear clamping vice. My first idea is to use the penalize tools but the tools force me to have a least 2 PCB in the panel. I want only one PCB because my reflow oven is small. I want something like this : It's possible to create this manually ? If not Did you have an idea to get a circular PCB into "cutable" square ? Thanks in advance #Skill#
rom1nux 2020-07-10 06:07:13 comment 6 0 Circuit Design
Unable to order PCB, Server Error 500
Hello, I m actually unable to order PCB on JLCPCB, Gerber file upload take a lot of time (at 91%) After trying to checkout, server return Error 500 I try with an other project I order since 3 days and this is the same behavior. Can you tell me when online order will be available ? #PCB#
rom1nux 2019-07-25 05:34:49 comment 2 0 PCB
Help : Track Length Tunning dont work on vertical track
All in the title, Track length tunning work well on horizontal track or oblique track but dont work on vertical track, You are able to draw the tuning on vertical track but it's not validated when you click, If someone have workaround please tell me I need to finish my board this week., Thanks in advance #BugReports#
rom1nux 2019-07-12 23:57:54 comment 0 0 Bug Reports
Track length not take account of via (PCB thickness)
Hello, All is in title : Create track on top of PCB with 200mm length net name "TEST1" Create track on top of PCB with 100mm length net name "TEST2", put a via (net name "TEST2") and create track on bottom of PCB with 100mm length net name "TEST2" Get the lenght from design manager "TEST1" and "TEST2" are the same, this is false, the via increase size of TEST2 for about the thickness of PCB #BugReports#
rom1nux 2019-07-12 18:14:40 comment 7 0 Bug Reports
Copper Area "Edit Points" Problem
Hello, Create new PCB in "mm" Put the grid to 2mm Create quicly square copper area Adjust the point with "Edit Points" tools As you see points are not at the good place ! Hope this help #BugReports#
rom1nux 2019-07-11 17:26:37 comment 4 0 Bug Reports
DFX export issue with board outline from PCB LIB
Hello, Create PCB LIB with board outline (like a board finger connector) Create PCB Add you lib component Complete the board outline Export the PCB as DXF. You can see only outline from PCB is exported, the outline from lib not exist in DXF. #BugReports#
rom1nux 2019-06-29 05:16:47 comment 6 0 Bug Reports
Option to remove GND tag under GND symbol
Hello, On schematic, please, have an option to remove "GND" tag under the ground symbol, because it pollutes the schematic reading... And it's not back compatible because before, no tag are added under ground symbol... Thank all the team for this very very good editor Have nice day #FeatureRequests#
rom1nux 2019-05-24 17:19:40 comment 6 0 Feature Requests
Shared project : Ground plane inconsistency, save flag and DRC miss
Hello, I got a big issue on my current project today, It's a shared project, my partner and I dont see the exact same project, the ground plane is not sync. When rebuild ground plane, the PCB tab is not marked as "*" (need to save). Also DRC dont catch the bridge and my real PCB goes to trash :( What my partner see : What I see As you see U7_7 is short circuit to ground plane. I dont know why project is not sync only on ground plane...I dont know why DRC dont catch this (Gound plane NET is GND\, whyt DRC let connect to U7_7)... I always check my file before production, I always rebuild ground plane before production and I always check DRC before production, I dont understand how this can append. The desync disturbing me This scarry me ! #BugReports#
rom1nux 2019-03-14 01:03:11 comment 7 0 Bug Reports
Stencil Production Progress "Temporarily No Data" since some month
Hello, Just for information, since two month the production progress for stencil is no more available "Temporarily No Data" . (Other production progress work without problem) Have nice day #PCB#
rom1nux 2019-03-08 06:43:03 comment 0 0 PCB
Create "Add node" item menu when right click on track
The actual method to add node at begin or end of track is really boring (sliding the last segment sometime dont work, sometime move entire track because of snap, etc...), this is really tedious. Please add an item on the menu when right click on track to quiclky add a node on a track without problem. "Add node" to add a node a the click location = quick and simple #FeatureRequests#
rom1nux 2019-03-06 21:14:16 comment 2 0 Feature Requests
Allow negative "Paste Mask Expansion" and "Solder Mask Expansion" coefficient
This allow to get solder paste stencil hole smaller than the pad. (See Footprint page 9 in http://www.st.com/content/ccc/resource/technical/document/datasheet/a7/86/d3/98/2c/7f/4b/d2/CD00217829.pdf/files/CD00217829.pdf/jcr:content/translations/en.CD00217829.pdf) #FeatureRequests#
rom1nux 2019-03-02 04:37:26 comment 14 0 Feature Requests
No version upgrade in some country !
Hello, On my workstation in France I am on V5.9.34, but I work in team, with remote machine in Switzerland and version is stuck in 5.8.20 (where there is some copper area bug) Why newer version is not proposed ? How to force EasyEDA to upgrade ? Have nice day #BugReports#
rom1nux 2019-01-16 03:24:36 comment 2 0 Bug Reports
Suddently copper Area overlap all top silk layer
Hello, I work all day on project without problem, but I just reopen the project and see copper area is not here. I rebuild and now copper area overlap all the top silk layer, I have to deselect all except top silk layer, select all (CTRL+A) and "Bring to front" to be able to work... Have nice day #BugReports#
rom1nux 2019-01-16 03:21:13 comment 2 0 Bug Reports
Will JLPCB be closed for the end of the year holidays if yes on which date ?
Hello, Can you tell me is your are going to shutdown activity for the end of the year holidays, and if yes, can, can you tell me the date ? Thanks in advance #PCB#
rom1nux 2018-12-10 17:29:52 comment 3 0 PCB
What are you doing with export ?
Hello, Since some day, there is a lot of problem with export functionality (Size = 0 bytes) ! ! It's a basic function ! Why this take so much time to fix a functionality that work perfectly before ? Please let us know what you are doing ? (Server problem, core, library bug, etc...) Hope this will be fix quickly... Courage #BugReports#
rom1nux 2018-11-30 20:48:10 comment 2 0 Bug Reports
Different pad to copper area connection for a specifics pads
Hello, Context : I want to put my enclosure to GND without wire, so I want my ground plan got two fine tape without varnish on opposite edge of both side of my PCB. This tape are going to make contact to the enclosure slide. To do this I create four big rectangular pads without hole in place of tape. I use a "radius connection" type on copper area parameters for all of my standard pad (it's easier for soldering) but EasyEDA do a radius connection on my rectangular tape pad too and a gap appear between tape and ground plan (It's connected but not completely, like a radius connection on small rectangular pad). To remove the gap, I trace GND track over the gap and all is OK, but it's tedious. Feature: I think it's a good thing to be able to consider existing "copper area connection type" as the default beavious of all pads, but also get a parameter on each pad to select specific connection type like [default, radius, direct], the default, use the copper area connection type parameter. A creation time, all pad are set to "connection type=default" to mimic the current behavior. But if I want I can choose "direct" for my for rectangular tape pad to get a continous and proper link to ground plan. Hope this is understandable, sorry for my bad English Have nice day #FeatureRequests#
rom1nux 2018-08-31 20:38:20 comment 5 0 Feature Requests
Lost default font and stange behavior on text modification
Hello, I create a project and produce it without problem since 15 days, I got ten very good PCB. Now I need to do some changes so I create new project and clone schematic and PCB from previous to new (With V5.7.54) (Edit : I just test and I got the problem all my project) I try to made change in text of serigraphy but the behavior is strange and I lost the default font (The previous EasyEDA default font) For example if I only change one letter in text, the font is changed (take look on the image) Before : After : (I just add x in front of text and press enter.. all change : font, size, etc...) I could not select default, I mean if I select default it's not the default font supply by EasyEDA before... I could not change the "line width" because of error message : "Changing line width for silhouette font wont work" Please could you fix this bug quickly, I could not produce my PCB because I could not change a simple text... Thanks in advance Rom1nux Bug still exist on : Version : 5.7.54 Browser: Firefox 61.0.2 (64 bits) and Chrome 68.0.3440.106 (64 bits) Project : All my project, look at public "12V Battery Level" #BugReports#
rom1nux 2018-08-31 08:01:21 comment 8 0 Bug Reports