When routing, if I grab a via and move it, if the wire cross another via or wire, it does not trigger a DRC error. If I grab the wire and move it in the same way, it does trigger a DRC.

Here's screenshots for reference.

Grabbing the via, no DRC triggered on B2
moving via attached to wire.png

Grabbing the B2 wire and dragging it, triggers the DRC error:
moving wire attached to via.png

#Bug Reports#
#BugReports#
Bug Reports