Non-descript error when launching a simulation with 2N2222

Hi all,

This is my first simulation in EasyEDA, so I expect I'm not seeing something very obvious:

Non-descript error when running simulation

I've read the simulation tutorials, and I was careful to choose the NPN model from the System/Spice Discrete list. I chose a 2N2222, but I actually don't care much: if needed I can change to another model. I took the passive components from the EELib, as I read that those do have spice model associated. I've tried a simulation without the NPN transistor, and it ran as expected, so I guess the models for passive components are right. As soon as I add the transistor, it starts giving me the non-descript error. I've tried other transistors, but result is always that non-descript error. I've also tried to create a new project from scratch, just in case I did something wrong with configuration. I've also tried changing the simulation parameters

I'm out of ideas, so if someone can help me...

Best regards,
   Jean-Michel Gonet

#Simulation#
Circuit Design
have a way to define a repeated subcircuit

Suppose I have a subcircuit which apperas many times inside a bigger circuit, it would be nice if there was a way to define its footprint only once.

My use case is: I am drawiing a board where there are many 8x8 led matrices, each driven by a MAX7219. The connection between 1 matrix and its MAX7219 requires 16 connections. I would like not to have to repeat it manually for each matrix.

I tried to achieve that with no luck both using new component or using sub-modules. Using modules, when I place many instances of a schemnatic module in a schematic, there is no way to decide whch net names are local to the schematic and which are global. Furthermore, when I convert to PCB, there is no way to make it use the PCB module corresponding to the schematc module. Using components, I get lot of conflicts with net names.

Please find below an example using components.

Example:
I create a PCB-LIB with two resistors in series (name MYCOMP):
    padR1_1- R1 padR1_2 - wire - padR2_1 - R2 - pad_R2_2
I create a SCHEMATIC-LIB (name MYCOMP) with two pins\, associated it with MYCOM PCB created above\, and tie the two pins with pad_R1_1 and pad_R2_2
I create a new project and place two components of type MYSCH.
Convert to the PCB
Now the problem is that the internal component connection "padR1_2 - wire - padR2_1" shows a DRC error.

Complicating a bit the example, let's say the schematic fro MYCOMP is defined using nets:
    NET_GND - padR1_1- R1 padR1_2 - NET_X1
    NET_X1   - padR2_1 - R2 - pad_R2_2
when I place an instance of MYCOMP on a manin schematic\, I would like to control how the net names are expanded: I want that NET_GND remains unchanged\, so that it is global\, while NET_X1 is prefixed with a unique string to make it local\, so that it remains local of this schematic. For instance I could define this using question marks\, to mark nets which are local:
    NET_GND - padR1_1- R1 padR1_2 - NET_X1?
    NET_X1?   - padR2_1 - R2 - pad_R2_2

Last it would e nice if when I define a new component like this, if I could choose for it to have global visibility ot project only visibility

#Feature Requests#
Feature Requests