Different results simulating the same netlist under EasyEDA and ngspice

Hi!

I obtained the below strange result simulating the operating point of the schematic fully_differential_unity_gain_buffer of my multisheet project LIA_testboard (https://easyeda.com/editor#id=t3leUc60i).

* EasyEDA result *****
Operating Point Simulation results:
+3v: -0.033617981192V voltage
v(volprobe3): -0.01209V voltage
v(volprobe4): -0.01209V voltage

Circuit: fully_differential_unity_gain_buffer

Doing analysis at TEMP = 27.000000 and TNOM = 27.000000

Warning: v2: no DC value, transient time 0 value used
Warning: v3: no DC value, transient time 0 value used

No. of Data Rows : 1

ngspice-26 done
* EasyEDA result *****

I then generated the netlist and copied it to http://www.ngspice.com/index.php and just changed the .control block by the .op command, as this web interface to ngspice do not support the .control block and simulated, obtaining the expected result.

* ngspice result *****
0 v(volprobe2) voltage 0 2.995575136386290e+00
32 v(volprobe4) voltage 8.990835684303878e-01
34 v(volprobe3) voltage 8.991239566547913e-01
104 v(volprobe1) voltage 1.797849754862354e+00
* ngspice result *****

Is this a bug? or am I doing, one more time, something wrong?

#Simulation#
Circuit Design
Multipart component numbering is broken.

BUG

Concise problem statement:

Bug report created in response to:

https://easyeda.com/forum/topic/multi_part_component-Tcke8qICU

Multipart components cannot be placed numbered as - for example a quad logic gate package - U1.1, U1.2, U1.3, U1.4.
Steps to reproduce bug:

  1. Place a single logic gate. Set Prefix to U1.1;

  2. Place a second single logic gate. Set Prefix to U1.2.

Results:

Second gate that should be U1.2 is numbered as U2.1 and a warning comes up that U1 already exist

Expected results:

Second gate should be numbered as U1.2.

  • Note that this used to work OK.

Browser:

#Bug Reports#
Bug Reports
User selectable keep or renumber netlabel numbering

Feature Request

Brief title for your desired feature:

As described in point (1) of:

https://easyeda.com/forum/topic/Label_changing_on_cut_paste-ttPN9usAW

If I select a bunch of net labels and copy-paste, EasyEDA changes the labels.

For example: if I copy ADDR0 to ADDR15 it pastes them as ADDR16 to ADDR31. I have to go through them one-by-one and change them back to ADDR0 to ADDR15.

How would you like the feature to work?

I the user needs to have the option to:

  1. copy and renumber so that copy ADDR0 to ADDR15 pastes them as ADDR16 to ADDR31;
  2. or, to copy and retain the numbering so that copy ADDR0 to ADDR15 pastes them as ADDR0 to ADDR15;

Why is this feature important to you?

Described above...

:)

#Feature Requests#
Feature Requests